Home > Products > Circuit Breaker > IEC Standard 12kv DC Indoor High-Voltage Vmv Vacuum Circuit Breaker

IEC Standard 12kv DC Indoor High-Voltage Vmv Vacuum Circuit Breaker

Basic Info

Model No.:  VMV

Product Description

Model NO.: VMV Operation: Manual & Electric Vacuum Circuit Breaker Arc-extinguishing Medium: Vacuum Structure: Vcb Vacuum Circuit Breaker Type: Circuit Breaker Certification: ISO9001-2000, Ohsas 180001 Rated Current: 630/ 1250/1600/2000/2500/3150/4000A Lightning Impulse Withstand Voltage: 75kv Vacuum Circuit Breaker Rated Short-Time Withstand Current: 20/25/31.5/40ka Vacuum Circuit Breaker Trademark: Mingde Vacuum Circuit Breaker Origin: Cixi, Ningbo Vacuum Circuit Breaker Breaking Capacity: Middle& High Voltage Vacuum Circuit Breaker Speed: Normal Type Circuit Breaker Installation: Fixed & Withdrawal Vacuum Circuit Breaker Poles Number: 3 Function: Overcurrent Protection Rated Voltage: 12kv Vacuum Circuit Breaker 1 Min Power Frequency Withstand Voltage: 42kv Vacuum Circuit Breaker Rated Frequency: 50 Hz Vacuum Circuit Breaker Rated Short-Circuit Breaking Current: 20/25/31.5/40ka Vacuum Circuit Breaker Specification: OHSAS/ OHSMS 18001, ISO9001 HS Code: 8535210000 IEC Standard 12kv DC Indoor High-voltage Vmv Vacuum Circuit Breaker  
Overview

1. A brand new series of products, wider use in different fields and environment
2. Mechanical life up to 60,000 times
3. Expandable to smart circuit breaker
 
Operation Mechanism

VMV Modularized Operation Mechanism
VMV Modularized Operation Mechanism (with smart unit)
   Modularized design of the operation mechanism is the highlights of VMV circuit breaker. With opening module and closing module in one part, the independent operation mechanism makes the standardized production and maintenance much easier.
 
Gear Driving System

We improved VMV circuit breakers' driving system, using the gear driving system instead of the traditional chain wheel driving system. The circuit breaker operation will run more smoothly with a longer mechanical life.

Opening Oil Buffer

The application of high-performance oil buffer can greatly reduce moving contact's over-swing and rebound during the circuit breakers' opening process. In this way, it avoids the reduction of mechanical life when vacuum interrupter is over-fatigue, resulted from contact's over-swing.
 
 Main Specifications and Technical Parameters
 
Item unit Data
Rated voltage kV 12
1 min power frequency withstand voltage kV 42
Lightning impulse withstand voltage kV 75
Rated frequency Hz 50
Rated current A 630,1250,
1600,2000,2500,3150,4000
Rated short-time withstand current kA 20,25,31.5,40
Rated peak withstand current kA 50,63,80,100
Rated short-circuit breaking current kA 20,25,31.5,40
Rated short-circuit closing current kA 50,63,80,100
Rated short-circuit duration S 4
Contact over-travel  mm 3.5±0.5
Clearance between open contacts mm 9±1/11±1
Average opening speed m/s 1.1±0.2
Average closing speed m/s 0.6±0.2
Opening time  ms 35-60
Closing time ms 20-45
Rated operation sequence   O-0.3s-CO-180s-CO(<40kA)/
O-180s-CO-180s-CO(≥40kA)
Mechanical life cycles 10000,30000,60000

External DimensionIEC Standard 12kv DC Indoor High-Voltage Vmv Vacuum Circuit Breaker VMV2-7.2,12-pole center distance 150mm 
No. Rated Voltage(kV) Rated current(A) Short-circuit breaking current(kA) h1(mm) h2(mm) h(mm) A(mm) B(mm)
1 7.2,12,17.5 630-1250 20-31.5 260 205 622 438 609
2 7.2,12,17.5 630-1250 20-31.5 280 275 637 432 598

IEC Standard 12kv DC Indoor High-Voltage Vmv Vacuum Circuit BreakerVMV2-7.2, 12, 17.5-pole center distance 210mm 
No. Rated Voltage(kV) Rated current(A) Short-circuit breaking current(kA) h1(mm) h2(mm) h(mm) A(mm) B(mm)
1 7.2,12,17.5 630-1250 20-31.5 260 205 622 438 609
2 7.2,12,17.5 630-1600 20-31.5 280 275 637 432 598
3 7.2,12 1250-1600 40 295 310 697 432 598
4 7.2,12 2000 31.5-40 295 310 697 432 598
 
IEC Standard 12kv DC Indoor High-Voltage Vmv Vacuum Circuit BreakerVMV2-7.2, 12, 17.5-pole center distance 275mm 
No. Rated Voltage(kV) Rated current(A) Short-circuit breaking current(kA) h1(mm) h2(mm) h(mm) A(mm) B(mm)
1 7.2,12,17.5 630-1250 20-31.5 280 275 637 432 598
2 7.2,12 1250-1600 40 295 310 697 432 598
3 7.2,12 1600-2500 25-40 295 310 697 432 586
4 7.2,12 3150-4000 31.5-40 295 310 697 432 586
5 7.2,12 3150-4000 31.5-40 295 310 733 432 586
 
 Normal Operating Environment Condition
a) Normal operating environment condition
Highest temperature:                  +40ºC
Lowest temperature:                   -15ºC
b) Environment humidity
Daily mean relative humidity:        ≤95%
Monthly mean relative humidity:     ≤90%
Daily mean saturated vapor pressure:   ≤2.2×10-3 MPa
Monthly mean saturated vapor pressure:  ≤1.8×10-3 MPa
c) Altitude: below 1000m area;
d) Earthquake intensity: no more than 8 degree;
e) The product shall be away from weep, fire and explosion, chemical corrosion and 
strenuous vibration place.

Special Operating Condition

Please consult with manufacturer on manufacturing technology when operating environment is the climatic environment with high altitude, high humidity and great temperature change or Other special environment condition.

Packaging, transportation and storage precautions

(1) Circuit breaker should be in the state of opening and energy storage spring in a state without energy storage when packing. It should be in the state of opening and energy storage spring in a state without energy storage when packing. And it should be fixed on the bottom of the wooden case, should have waterproof measures and complete package labels.
(2) Circuit breakers can't invert and avoid strong vibration, rain, surface damage, and components lost when transportation.
(3) When loading the circuit breaker, we suggest the following tools: crane, forklift and driving. When lifting the circuit breaker, we should not hook on the body or pole of the circuit breaker, but on the lifting hole which has the lifting mark.
(4) When circuit breaker has a long-term storage, it should be in a state of opening and energy storage spring in a state without energy storage and placed in dry ventilated indoor preventing from moisture, vibration control and harmful gas erosion, and regularly checked whether environment meets the requirements.
(5)When first use products after long-term storage, it need to have a power frequency withstand voltage Insulation testing.

Contact us if you need more details on Circuit Breaker. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Vacuum Interrupter、Vacuum Circuit Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.