Basic Info
Model No.: VMV
Product Description
Model NO.: VMV
Operation: Manual & Electric Circuit Breaker
Arc-extinguishing Medium: Vacuum
Structure: Vcb Circuit Breaker
Type: Circuit Breaker
Certification: ISO9001-2000, Ohsas 180001
Rated Current: 1600A Circuit Breaker
mechanical Life: 10000times Circuit Breaker
Transport Package: Wooden Case Circuit Breaker
Origin: Zhejiang Ningbo Circuit Breaker
Breaking Capacity: Middle& High Voltage Circuit Breaker
Speed: Normal Type Circuit Breaker
Installation: Fixed & Withdrawalable Circuit Breaker
Poles Number: 3
Function: Overcurrent Protection
Rated Voltage: 17.5kv Circuit Breaker
Rated Frequency: 50Hz Circuit Breaker
Trademark: Mingde Circuit Breaker
Specification: OHSAS/ OHSMS 18001, ISO9001
HS Code: 8535210000
17.5kV Medium-voltage Electric DC Circuit Breaker of VMV Series
Product Overview
1. A brand new series of products, wider use in different fields and environment
2. Mechanical life up to 60,000 times
3. Expandable to smart circuit breaker
Operation Mechanism
VMV Modularized Operation Mechanism
VMV Modularized Operation Mechanism (with smart unit)
Modularized design of the operation mechanism is the highlights of VMV circuit breaker. With opening module and closing module in one part, the independent operation mechanism makes the standardized production and maintenance much easier.
Gear Driving System
We improved VMV circuit breakers' driving system, using the gear driving system instead of the traditional chain wheel driving system. The circuit breaker operation will run more smoothly with a longer mechanical life.
Opening Oil Buffer
The application of high-performance oil buffer can greatly reduce moving contact's over-swing and rebound during the circuit breakers' opening process. In this way, it avoids the reduction of mechanical life when vacuum interrupter is over-fatigue, resulted from contact's over-swing.
Main Specifications and Technical Parameters
Item | unit | Data |
Rated voltage | kV | 17.5 |
1 min power frequency withstand voltage | kV | 50 |
Lightning impulse withstand voltage | kV | 95 |
Rated frequency | Hz | 50 |
Rated current | A | 1600 |
Rated short-time withstand current | kA | 20,25,31.5 |
Rated peak withstand current | kA | 50,63,80 |
Rated short-circuit breaking current | kA | 20,25,31.5 |
Rated short-circuit closing current | kA | 50,63,80 |
Rated short-circuit duration | S | 4 |
Contact over-travel | mm | 3.5±0.5 |
Clearance between open contacts | mm | 9±1/11±1 |
Average opening speed | m/s | 1.1±0.2 |
Average closing speed | m/s | 0.6±0.2 |
Opening time | ms | 35-60 |
Closing time | ms | 20-45 |
Rated operation sequence | O-0.3s-CO-180s-CO(<40kA)/ O-180s-CO-180s-CO(≥40kA) | |
Mechanical life | cycles | 10000 |
External Dimension
VMV2-7.2, 12, 17.5-pole center distance 210mm
No. | Rated Voltage(kV) | Rated current(A) | Short-circuit breaking current(kA) | h1(mm) | h2(mm) | h(mm) | A(mm) | B(mm) |
1 | 7.2,12,17.5 | 630-1250 | 20-31.5 | 260 | 205 | 622 | 438 | 609 |
2 | 7.2,12,17.5 | 630-1600 | 20-31.5 | 280 | 275 | 637 | 432 | 598 |
3 | 7.2,12 | 1250-1600 | 40 | 295 | 310 | 697 | 432 | 598 |
4 | 7.2,12 | 2000 | 31.5-40 | 295 | 310 | 697 | 432 | 598 |
VMV2-7.2, 12, 17.5-pole center distance 275mm
No. | Rated Voltage(kV) | Rated current(A) | Short-circuit breaking current(kA) | h1(mm) | h2(mm) | h(mm) | A(mm) | B(mm) |
1 | 7.2,12,17.5 | 630-1250 | 20-31.5 | 280 | 275 | 637 | 432 | 598 |
2 | 7.2,12 | 1250-1600 | 40 | 295 | 310 | 697 | 432 | 598 |
3 | 7.2,12 | 1600-2500 | 25-40 | 295 | 310 | 697 | 432 | 586 |
4 | 7.2,12 | 3150-4000 | 31.5-40 | 295 | 310 | 697 | 432 | 586 |
5 | 7.2,12 | 3150-4000 | 31.5-40 | 295 | 310 | 733 | 432 | 586 |
Packaging, transportation and storage precautions
(1) Circuit breaker should be in the state of opening and energy storage spring in a state without energy storage when packing. It should be in the state of opening and energy storage spring in a state without energy storage when packing. And it should be fixed on the bottom of the wooden case, should have waterproof measures and complete package labels.
(2) Circuit breakers can't invert and avoid strong vibration, rain, surface damage, and components lost when transportation.
(3) When loading the circuit breaker, we suggest the following tools: crane, forklift and driving. When lifting the circuit breaker, we should not hook on the body or pole of the circuit breaker, but on the lifting hole which has the lifting mark.
(4) When circuit breaker has a long-term storage, it should be in a state of opening and energy storage spring in a state without energy storage and placed in dry ventilated indoor preventing from moisture, vibration control and harmful gas erosion, and regularly checked whether environment meets the requirements.
(5)When first use products after long-term storage, it need to have a power frequency withstand voltage Insulation testing.
Certificates
Contact us if you need more details on Circuit Breaker. We are ready to answer your questions on packaging, logistics, certification or any Other aspects about Breaker、Vacuum Circuit Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Circuit Breaker
Premium Related Products
Other Products
Hot Products
Fuse Combination Unit Load Break Switch with Grounding Knife-Yfn5-12r (T) D/125-31.5Reasonble Price for Zinc-Oxide Lightning ArresterCkg Series High-Voltage Vacuum ContactorFn5-12r (T) D-Hv Load Switch with Reasonable Price.Hxgn-24 Indoor Ring Net Cabinet with High Quality, Reasonble PriceBest Selling, Reasonable Price&Good Service of Yfzn35-40.5 Series Vacuum Load Switch with FuseYFZRN-24 AC Hv Vacuum Load Switch with Safe and Easy Fuse12kv Series Factory Manufacture High-Voltage Isolating Switch--Yfg38-12D12kv Vacuum Arc Extinction High-Voltage Circuit Breaker Indoor Use -Vs1Fn5-12r (T) D Indoor AC Hv Load Switch-Fuse Combination UnitContact Box Md/150Mdgear 550 Solid Insulation Metal-Clad SwitchgearKyn61 Clad-Metal Drawable AC Metal Closed Switchgear550 Modularized Omni-Sealed Solid Insulation Metal-Clad Switchgear12kv Vs1 Indoor High-Voltage Vacuum Circuit Breaker with Embedded Pole12kv 630A Vmd Hv Electric Vacuum Breaker