Find Indoor HV Isolating Switch, Scientific And National Structure, Disconnector Switch on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Indoor HV Isolating Switch > Factory Supply Indoor Use Hv Disconnector Switch-Yfgn-24/630

Factory Supply Indoor Use Hv Disconnector Switch-Yfgn-24/630

Basic Info

Model No.:  YFGN-24/630

Product Description



Model NO.: YFGN-24/630


Structure: Three-column Disconnector


Operation: Manual or Electric


Number of Poles: Three Pole


Structure of Operating: Electric


Trademark: YF




Type: High-voltage


Installation: Indoor High-voltage


Grounding Mode: Grounding


Series: Three


Certification: ISO, CE, ISO9001


Origin: Jiangyin Yunfeng, China


Product Overview

YFGN-24/630 indoor AC HV disconnector is applied at the site with rated voltage of 24kV and rated frequency of 50Hz. It is a switch with obvious safe isolating fracture designed and developed independently according to GB3804, guaranteeing the system safety accordingly. Such model of disconnector has features of small size, simple but reasonable structure, small operation force, reliable performance and convenient maintenance, ect. It can be use with 24kV HV Circuit Breaker in the cabinet and it is a HV disconnector with advantageous cost performance.



Model Specification

Factory Supply Indoor Use Hv Disconnector Switch-Yfgn-24/630

Note: The sensor with live display can be used for the Switch Insulator.



Factory Supply Indoor Use Hv Disconnector Switch-Yfgn-24/630



Characteristics

a.small size

b.simple but reasonable structure

c.small operation force

d.reliable performance

e.convenient maintenance





Service Conditions

1.Altitude:2000m;

2.Ambient temperature-25ºC-+ 40ºC;

3.The daily average of relative humidity shall not be larger than 95% and the monthly average shall not be larger than 90%:

4.The ambient air shall not be subject to the obvious pollution such as corrosive or combustible gas and steam;

5.The site without fire hazards and explosion hazards;

6.The site that the seismic intensity does not exceed degree 8; the gradient shall not exceed 5°





Factory Supply Indoor Use Hv Disconnector Switch-Yfgn-24/630





Main Technical Parameters

Serial No. Item Unit Disconnector
1 Rated voltage kV 24
2 Rated frequency Hz 50
3 Rated current A 630
4 Rated peak withstand current kA 63
5 Rated short-time withstand current(4 seconds) kA 25
6 1min power-frequency withstand voltage(effective value) to earth, phase-to-phase/isloating fracture kV/kV 65/79
7 Full-wave lightning impulse withstand voltage(peak)to earth,phase-to-phase/isolating fracture kV/kV 125/145
8 Main loop resistance μΩ ≤50
9 Phase-to-phase center distance mm 275±3 or 250±3
10 Open distance of isolation contact knife switch mm ≥200
11 Maximum manual operation torque N ≤200
12 Three-phase opening and closng asynchronization ms ≤1




Factory Supply Indoor Use Hv Disconnector Switch-Yfgn-24/630

Contact us if you need more details on Load Switchgear. We are ready to answer your questions on packaging, logistics, certification or any Other aspects about Indoor Use、Disconnector Switch. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Indoor HV Isolating Switch