Pole Mounted 17.5kv-1250A 50Hz Vs1 Vacuum Circuit Breaker
Basic Info
Model No.: Mingde VS1
Product Description
Prodcut Overview
1. VS1A series of vacuum circuit breakers are the Second Generation indoor switch equipment, with the rated voltage 7.2kv, 12kv, 17.5kv and 24kv.
2. VS1A series of vacuum circuit breakers adopt the integrated design of simple structure and convenient operation.
3. It is equipped with a perfect mechanical and electrical interlock to enhance its anti-incorrect operation performance.
4. Standards: IEC62271-100, IEC56, GB1984-2003, GB/T11022, DL/T403-2000, etc Technical Specifications and Parameters
NO | Item | Unit |
| |
1 | Rated voltage | KV | 17.5 | |
2 | Rated insulating level | Rated short time power frequency withstand voltage (1 min) | 50 | |
Rated lighting impulse withstand voltage | 95 | |||
3 | Rated Frequency | Hz | 50 | |
4 | Rated current | A | 1250
| |
5 | Rated short circuit breaking current | KA | 20/25/31.5 | |
6 | Rated short time withstand current | 20/25/31.5 | ||
7 | Rated peak withstand current | 50/63/80 | ||
8 | 4S rated short-time withstand current | 20/25/31.5 | ||
9 | Rated peak value of current | 50/63/80 | ||
10 | Rated short-circuit making current(peak value) | 50/63/80 | ||
11 | Duration of rated short-circuit current | S | 4 | |
12 | Mechanical endurance | times | 10000,30000,60000 | |
13 | Rated making surge current of capacitor | KA | 12.5(The frequency is less than 1000Hz) | |
14 | Rated breaking current of single/symmetrical capacitor bank | A | 630,400(40KA for 800/400) | |
15 | Breaking times at rated short-circuit current | Times | 20 | |
16 | Power frequency withstand voltage of secondary circuit | V | 2000 | |
17 | Rated operating voltage | AC110/220 DC110/220 | ||
18 | Rated operating order |
| O-0.3S-CO-180S-CO | |
19 | Energy storage times | S | <=5 | |
20 | Clearance | mm | 9 ± 1 | |
21 | Travel | 3-4 | ||
22 | Bounce time(making) | ms | <=2 | |
23 | Three pole making/breaking non simultaneity | <=2 | ||
24 | Average breaking time | m/s | 0.9~1.3 | |
25 | Average making time | 0.4~0.8 | ||
26 | Making time | ms | 20-50 | |
27 | Breaking time | 35-70 | ||
28 | Contact Opening Bounce amplitude Value | mm | <=3 |
External Dimension
VS1A-7.2,12,17.5-pole center distance 150mm
No. | Rated Voltage(kV) | Rated current(A) | Short-circuit breaking current(kA) | h1(mm) | h2(mm) | h(mm) | A(mm) | B(mm) |
1 | 7.2,12 | 630-1250 | 20-31.5 | 260 | 205 | 622 | 438 | 609 |
2 | 7.2,12,17.5 | 630-1250 | 20-31.5 | 280 | 275 | 637 | 432 | 598 |
VS1A-7.2, 12, 17.5-pole center distance 210mm
No. | Rated Voltage(kV) | Rated current(A) | Short-circuit breaking current(kA) | h1(mm) | h2(mm) | h(mm) | A(mm) | B(mm) |
1 | 7.2,12,17.5 | 630-1250 | 20-31.5 | 260 | 205 | 622 | 438 | 609 |
2 | 7.2,12,17.5 | 630-1600 | 20-31.5 | 280 | 275 | 637 | 432 | 598 |
3 | 7.2,12 | 1250-1600 | 40 | 295 | 310 | 697 | 432 | 598 |
4 | 7.2,12 | 2000 | 31.5-40 | 295 | 310 | 697 | 432 | 598 |
VS1A-7.2, 12, 17.5-pole center distance 275mm
No. | Rated Voltage(kV) | Rated current(A) | Short-circuit breaking current(kA) | h1(mm) | h2(mm) | h(mm) | A(mm) | B(mm) |
1 | 7.2,12,17.5 | 630-1250 | 20-31.5 | 280 | 275 | 637 | 432 | 598 |
2 | 7.2,12 | 1250-1600 | 40 | 295 | 310 | 697 | 432 | 598 |
3 | 7.2,12 | 1600-2500 | 25-40 | 295 | 310 | 697 | 432 | 586 |
4 | 7.2,12 | 3150-4000 | 31.5-40 | 295 | 310 | 697 | 432 | 586 |
5 | 7.2,12 | 3150-4000 | 31.5-40 | 295 | 310 | 733 | 432 | 586 |
Normal Operating Environment Condition
a) Normal operating environment condition
Highest temperature: +40ºC
Lowest temperature: -15ºC
b) Environment humidity
Daily mean relative humidity: ≤95%
Monthly mean relative humidity: ≤90%
Daily mean saturated vapor pressure: ≤2.2×10-3 MPa
Monthly mean saturated vapor pressure: ≤1.8×10-3 MPa
c) Altitude: below 1000m area;
d) Earthquake intensity: no more than 8 degree;
e) The product shall be away from weep, fire and explosion, chemical corrosion and
strenuous vibration place.
Special Operating Condition
Please consult with manufacturer on manufacturing technology when operating environment is the climatic environment with high altitude, high humidity and great temperature change or Other special environment condition.
Packaging, transportation and storage precautions
(1) Circuit breaker should be in the state of opening and energy storage spring in a state without energy storage when packing. It should be in the state of opening and energy storage spring in a state without energy storage when packing. And it should be fixed on the bottom of the wooden case, should have waterproof measures and complete package labels.
(2) Circuit breakers can't invert and avoid strong vibration, rain, surface damage, and components lost when transportation.
(3) When loading the circuit breaker, we suggest the following tools: crane, forklift and driving. When lifting the circuit breaker, we should not hook on the body or pole of the circuit breaker, but on the lifting hole which has the lifting mark.
(4) When circuit breaker has a long-term storage, it should be in a state of opening and energy storage spring in a state without energy storage and placed in dry ventilated indoor preventing from moisture, vibration control and harmful gas erosion, and regularly checked whether environment meets the requirements.
(5)When first use products after long-term storage, it need to have a power frequency withstand voltage Insulation testing.
Contact us if you need more details on Circuit Breaker. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Vacuum Circuit Breaker、Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.