Home > Products > Circuit Breaker > Side Mounted 1600A Vmd Embedded Poles Circuit Breaker 17.5kv

Side Mounted 1600A Vmd Embedded Poles Circuit Breaker 17.5kv

Basic Info

Model No.:  VMD

Product Description

Model NO.: VMD Operation: Manual & Electric DC Circuit Breaker Arc-extinguishing Medium: Vcb DC Circuit Breaker Structure: Vcb DC Circuit Breaker Type: Circuit Breaker Certification: ISO9001-2000 Rated Current: 1600A DC Circuit Breaker Lightning Impulse Withstand Voltage: 95 Kv DC Circuit Breaker Rated Short-Time Withstand Current: 25/31.5 Ka DC Circuit Breaker Rated Short-Circuit Breaking Current: 25/31.5 Ka DC Circuit Breaker Transport Package: Wooden Case Packing (900*900*1000mm) Origin: Cixi, Ningbo DC Circuit Breaker Breaking Capacity: Middle& High Voltage DC Circuit Breaker Speed: Normal Type Circuit Breaker Installation: Fixed & Withdrawal DC Circuit Breaker Poles Number: 3 Function: Overcurrent Protection Rated Voltage: 17.5kv DC Circuit Breaker 1 Min Power Frequency Withstand Voltage: 50 Kv DC Circuit Breaker Rated Frequency: 50 Hz DC Circuit Breaker Rated Peak Withstand Current: 63/80 Ka DC Circuit Breaker Trademark: Mingde DC circuit breaker Specification: OHSAS/ OHSMS 18001, ISO9001 HS Code: 8535210000 Side Mounted 1600A Vmd Embedded Poles Circuit Breaker 17.5kv

Overview
   1. The complete specification of VMD series Vacuum Circuit Breaker can meet customers' different needs.
  2. VMD adopts the latest embedded poles and low-resistance vacuum interrupter. With main conductive circuit sealed in epoxy resin, the Insulation performance will be more stable.
  3. VMD employs an accurate gear driving system, instead of the traditional chain wheel driving system.  
  4. VMD series circuit breaker passed Type Test Report according to GB and IEC standards.
  5. VMD series circuit breaker has exported to 26 countries and regions in the world.   
Main parameters

    
Item unit Data
Rated voltage kV 17.5
1 min power frequency withstand voltage kV 50
Lightning impulse withstand voltage kV 95
Rated frequency Hz 50
Rated current
 
A 1600
Rated short-time withstand current kA 25, 31.5
Rated peak withstand current kA 50,63,80
Rated short-circuit breaking current kA 20,25,31.5
Rated short-circuit closing current kA 50,63
Rated short-circuit duration S 4
Contact over-travel  mm 3.5±0.5
Clearance between open contacts mm 9±1/11±1
Average opening speed m/s 1.1±0.2
Average closing speed m/s 0.6±0.2
Opening time  ms 35-60
Closing time ms 20-45
Rated operation sequence   O-0.3s-CO-180s-CO(<40kA)/
O-180s-CO-180s-CO(≥40kA)
Mechanical life cycles 10000,30000
 
External Dimension 

Side Mounted 1600A Vmd Embedded Poles Circuit Breaker 17.5kv
 VMD2-7.2, 12, 17.5-pole center distance 210mm 
No. Rated Voltage(kV) Rated current(A) Short-circuit breaking current(kA) h1(mm) h2(mm) h(mm) A(mm) B(mm)
1 7.2,12,17.5 630-1250 20-31.5 260 205 622 438 609
2 7.2,12,17.5 630-1600 20-31.5 280 275 637 432 598
3 7.2,12 1250-1600 40 295 310 697 432 598
4 7.2,12 2000 31.5-40 295 310 697 432 598

Side Mounted 1600A Vmd Embedded Poles Circuit Breaker 17.5kvVMD2-7.2, 12, 17.5-pole center distance 275mm 
No. Rated Voltage(kV) Rated current(A) Short-circuit breaking current(kA) h1(mm) h2(mm) h(mm) A(mm) B(mm)
1 7.2,12,17.5 630-1250 20-31.5 280 275 637 432 598
2 7.2,12 1250-1600 40 295 310 697 432 598
3 7.2,12 1600-2500 25-40 295 310 697 432 586
4 7.2,12 3150-4000 31.5-40 295 310 697 432 586
5 7.2,12 3150-4000 31.5-40 295 310 733 432 586
  Packaging, transportation and storage precautions

(1) Circuit breaker should be in the state of opening and energy storage spring in a state without energy storage when packing. It should be in the state of opening and energy storage spring in a state without energy storage when packing. And it should be fixed on the bottom of the wooden case, should have waterproof measures and complete package labels.
(2) Circuit breakers can't invert and avoid strong vibration, rain, surface damage, and components lost when transportation.
(3) When loading the circuit breaker, we suggest the following tools: crane, forklift and driving. When lifting the circuit breaker, we should not hook on the body or pole of the circuit breaker, but on the lifting hole which has the lifting mark.
(4) When circuit breaker has a long-term storage, it should be in a state of opening and energy storage spring in a state without energy storage and placed in dry ventilated indoor preventing from moisture, vibration control and harmful gas erosion, and regularly checked whether environment meets the requirements.
(5)When first use products after long-term storage, it need to have a power frequency withstand voltage insulation testing.
Side Mounted 1600A Vmd Embedded Poles Circuit Breaker 17.5kvCertification

Side Mounted 1600A Vmd Embedded Poles Circuit Breaker 17.5kv

Contact us if you need more details on Circuit Breaker. We are ready to answer your questions on packaging, logistics, certification or any Other aspects about Breaker、Vacuum Circuit Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Circuit Breaker